When applying the inverted coefficients, a curve (see Figure 30) will result that effectively neutralizes the original crystal
characteristics. The frequencies were calculated using the fit coefficients as follows:
f = f nom ? ? 1 +
?
?
?
a
10
6
+ T
b
10
6
+ T 2
c ?
10 6 ?
32768.5
32768.4
32768.3
32768.2
32768.1
32768
32767.9
32767.8
32767.7
32767.6
32767.5
crystal
curve fit
inverse curve
-50
-25
0
25
50
Figure 30: Crystal Compensation
The MPU Demo Code supplied with the TERIDIAN Demo Kits has a direct interface for these coefficients and it directly con-
trols the RTC_DEC_SEC or RTC_INC_SEC registers. The Demo Code uses the coefficients in the following form:
CORRECTION ( ppm ) =
Y _ CAL
10
+ T ?
Y _ CALC
100
+ T 2 ?
Y _ CALC 2
1000
Note that the coefficients are scaled by 10, 100, and 1000 to provide more resolution. For our example case, the coefficients
would then become (after rounding, since the Demo Code accepts only integers):
Y_CAL = 109, Y_CALC = 12, Y_CALC2 = 7
Alternatively, the mains frequency may be used to stabilize or check the function of the RTC. For this purpose, the CE
provides a count of the zero crossings detected for the selected line voltage in the MAIN_EDGE_X address. This count is
equivalent to twice the line frequency, and can be used to synchronize and/or correct the RTC.
External Temperature Compensation
In a production electricity meter, the 71M6511 or 71M6511H is not the only component contributing to temperature de-
pendency. In fact, a whole range of components (e.g. current transformers, resistor dividers, power sources, filter capacitors)
will exhibit slight or pronounced temperature effects. Since the output of the on-chip temperature sensor is accessible to the
MPU, temperature-compensation mechanisms with great flexibility, i.e. beyond the capabilities implemented in the CE, are
possible.
Temperature Measurement
Temperature measurement can be implemented with the following steps:
1)
2)
3)
At a known temperature T N , read the TEMP_RAW register of the CE and write the value into TEMP_NOM .
Read the TEMP_X register at the known temperature. The obtained value should be < ± 0.1°C.
The temperature T (in °C) at any environment can be obtained by reading TEMP_X and applying the following
formula:
T = T N +
TEMP _ X
10
Page: 79 of 98
? 2005–2010 Teridian Semiconductor Corporation
V2.7
相关PDF资料
71M6513H-IGT/F IC ENERGY METER 3PH 100-LQFP
71M6515H-IGT/F IC ENERGY METER AFE 3PH 64-LQFP
71M6521BE-IGTR/F IC ENERGY METER 8K FLASH 64-LQFP
71M6533G-IGTR/F IC ENERGY METER 3PH 100LQFP
71M6543F-IGT/F IC ENERGY METERING
71M6545-IGT/F IC ENERGY METERING
720-10007-00300 CBL D-SUB 9PIN FMAL-25PIN FML 3M
720-10010-00025 CBL DSUB 9PIN FML-25PIN MAL .25M
相关代理商/技术参数
71M6511-IGT 制造商:TERIDIAN 制造商全称:TERIDIAN 功能描述:Single-Phase Energy Meter IC
71M6511-IGT/F 功能描述:计量片上系统 - SoC Highly Integrated SoC w/MCU Core RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6511-IGT/F1 功能描述:计量片上系统 - SoC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6511-IGTR 制造商:TERIDIAN 制造商全称:TERIDIAN 功能描述:Single-Phase Energy Meter IC
71M6511-IGTR/F 功能描述:计量片上系统 - SoC Highly Integrated SoC w/MCU Core RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6511-IGTR/F1 功能描述:计量片上系统 - SoC RoHS:否 制造商:Maxim Integrated 核心:80515 MPU 处理器系列:71M6511 类型:Metering SoC 最大时钟频率:70 Hz 程序存储器大小:64 KB 数据 RAM 大小:7 KB 接口类型:UART 可编程输入/输出端数量:12 片上 ADC: 安装风格:SMD/SMT 封装 / 箱体:LQFP-64 封装:Reel
71M6512-DB 制造商:Maxim Integrated Products 功能描述:Development Boards & Kits - 8051 71M6512 Demo Brd
71M6512-IM/F 制造商:Maxim Integrated Products 功能描述:Metering Systems on a Chip - SoC Residential Meter Extended Io